- 1Scope
This specification covers the general requirements of corrugated high density polyethylene pipe for use in roadway subdrain and related construction applications.
-
2Material
Pipe shall be manufactured from high density polyethylene resin, which shall meet or exceed the requirements of cell classification 324420C as defined in ASTM D3350. Resistant to a wide range of soil acidity: pH 1.25 to 14.
-
3Joining Systems
The pipe shall be joined with insert or split (wrap) couplers.
-
4Pipe Stiffness
Pipe shall have minimum pipe stiffness of 320 kPa at 5% deflection when tested in accordance with ASTM D2412
-
5Hydraulics
The following Manning's 'n' values shall be used to calculate flow. See CPPA Technical Hydraulic booklet available from Ideal Pipe or the Plastics Pipe Institute.
| I.D. mm | 100 (4") |
150 (6") |
200 (8") |
250 (10") |
300 (12") |
| 'n' | 0.017 | 0.017 | 0.018 | 0.019 | 0.020 |
-
6Structural Design
Structural design shall conform to the industy accepted procedures found in the Corrugated Polyethylene Pipe Association's technical booklets from Ideal Pipe or the Plastics Pipe Institute.
-
7Applicable Standards
OPSS 1840; 421
OPSD 806.02
-
8Options
Available as solid, perforated or filtered pipe.
-
9Pipe Dimensions
CHALLENGER 1000 is available in diameters from 100 mm (4") to 300 mm (12") and in selective coil sizes 50 ft. to 4000 ft. or length sections of 20 ft. Nominal pipe size is based on inside diameter of the pipe.